{"id":5255,"date":"2026-07-08T15:34:01","date_gmt":"2026-07-08T13:34:01","guid":{"rendered":"https:\/\/www.toulouse-white-biotechnology.com\/?post_type=documentations&#038;p=5255"},"modified":"2026-07-08T16:35:03","modified_gmt":"2026-07-08T14:35:03","slug":"process-development-and-scale-up-for-vibrio-natriegens-from-biolector-xtmicrobioreactor-to-pre-pilot-scale","status":"publish","type":"documentations","link":"https:\/\/www.toulouse-white-biotechnology.com\/en\/insights\/documentation\/note-technologique\/process-development-and-scale-up-for-vibrio-natriegens-from-biolector-xtmicrobioreactor-to-pre-pilot-scale\/","title":{"rendered":"Process Development and Scale-up for Vibrio natriegens: From BioLector XTMicrobioreactor to Pre-pilot Scale"},"content":{"rendered":"\n<h2 class=\"wp-block-heading has-h-5-font-size\">APPLICATION NOTE<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-full\"><picture><source srcset=\"https:\/\/www.toulouse-white-biotechnology.com\/app\/uploads\/2026\/07\/twb-beckman-coulter-life-sciences-partnership-biolector-application-note.webp 1x, https:\/\/www.toulouse-white-biotechnology.com\/app\/uploads\/2026\/07\/twb-beckman-coulter-life-sciences-partnership-biolector-application-note@2x.webp 2x\" type=\"image\/webp\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.toulouse-white-biotechnology.com\/app\/uploads\/2026\/07\/twb-beckman-coulter-life-sciences-partnership-biolector-application-note.jpg\" alt=\"Twb Beckman Coulter Life Sciences Partnership Biolector Application Note\" class=\"wp-image-5264\" srcset=\"https:\/\/www.toulouse-white-biotechnology.com\/app\/uploads\/2026\/07\/twb-beckman-coulter-life-sciences-partnership-biolector-application-note.jpg 1024w, https:\/\/www.toulouse-white-biotechnology.com\/app\/uploads\/2026\/07\/twb-beckman-coulter-life-sciences-partnership-biolector-application-note-300x300.jpg 300w, https:\/\/www.toulouse-white-biotechnology.com\/app\/uploads\/2026\/07\/twb-beckman-coulter-life-sciences-partnership-biolector-application-note-150x150.jpg 150w, https:\/\/www.toulouse-white-biotechnology.com\/app\/uploads\/2026\/07\/twb-beckman-coulter-life-sciences-partnership-biolector-application-note-768x768.jpg 768w, https:\/\/www.toulouse-white-biotechnology.com\/app\/uploads\/2026\/07\/twb-beckman-coulter-life-sciences-partnership-biolector-application-note-80x80.jpg 80w, https:\/\/www.toulouse-white-biotechnology.com\/app\/uploads\/2026\/07\/twb-beckman-coulter-life-sciences-partnership-biolector-application-note-65x65.jpg 65w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/picture><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"wp-block-paragraph\"><strong><em>Authors:<\/em><\/strong><br>Tiphaine Clement, <em>TWB<\/em><br>Joanna Abboud, <em>TWB<\/em><br>Anna Kress &amp; Noud Drummen, <em>Beckman Coulter Life Sciences<\/em><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Abstract<\/h3>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\">Optimization, scalability and transferability represent key challenges in bioprocess development. In<br>this study, scalable fermentation processes for Vibrio natriegens were explored using the BioLector XT<br>Microbioreactor. Initial cultivation parameters, including glycerol concentration (20, 30 and 50 g\/L),<br>inoculation density (OD\u2086\u2080\u2080 0.1-0.5) and induction timing were systematically evaluated. Different feeding<br>strategies (constant, linear, exponential) and feed medium compositions (1\u00d7 and 4\u00d7 VN medium) were<br>compared to optimize mScarlet production. Two optimized process conditions were subsequently<br>transferred to 20-L bioreactors to validate scalability. The high-performance process (4\u00d7 VN feed,<br>feed start at four hours) achieved 1.8-fold higher biomass compared to the low-performance process<br>(1\u00d7 VN feed, feed start at eight hours) in both scales. A strong correlation was observed between the<br>BioLector XT Microbioreactor and the 20-L bioreactor performance, demonstrating successful process<br>transferability. The data obtained in the BioLector XT instrument, regarding medium composition and<br>process strategy, was representative of what was observed in the 20-L bioreactor, allowing strong<br>confidence in the scalability and transferability of processes developed at microscale and providing<br>better understanding of V. natriegens physiology.<\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>APPLICATION NOTE Authors:Tiphaine Clement, TWBJoanna Abboud, TWBAnna Kress &amp; Noud Drummen, Beckman Coulter Life Sciences Abstract Optimization, scalability and transferability represent key challenges in bioprocess development. Inthis study, scalable fermentation processes for Vibrio natriegens were explored using the BioLector XTMicrobioreactor. Initial cultivation parameters, including glycerol concentration (20, 30 and 50 g\/L),inoculation density (OD\u2086\u2080\u2080 0.1-0.5) and [&hellip;]<\/p>\n","protected":false},"featured_media":5264,"parent":0,"template":"","tags":[],"type-de-document":[11],"class_list":["post-5255","documentations","type-documentations","status-publish","has-post-thumbnail","hentry","type-de-document-note-technologique"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.toulouse-white-biotechnology.com\/en\/wp-json\/wp\/v2\/documentations\/5255","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.toulouse-white-biotechnology.com\/en\/wp-json\/wp\/v2\/documentations"}],"about":[{"href":"https:\/\/www.toulouse-white-biotechnology.com\/en\/wp-json\/wp\/v2\/types\/documentations"}],"version-history":[{"count":6,"href":"https:\/\/www.toulouse-white-biotechnology.com\/en\/wp-json\/wp\/v2\/documentations\/5255\/revisions"}],"predecessor-version":[{"id":5268,"href":"https:\/\/www.toulouse-white-biotechnology.com\/en\/wp-json\/wp\/v2\/documentations\/5255\/revisions\/5268"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.toulouse-white-biotechnology.com\/en\/wp-json\/wp\/v2\/media\/5264"}],"wp:attachment":[{"href":"https:\/\/www.toulouse-white-biotechnology.com\/en\/wp-json\/wp\/v2\/media?parent=5255"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.toulouse-white-biotechnology.com\/en\/wp-json\/wp\/v2\/tags?post=5255"},{"taxonomy":"type-de-document","embeddable":true,"href":"https:\/\/www.toulouse-white-biotechnology.com\/en\/wp-json\/wp\/v2\/type-de-document?post=5255"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}